婷婷成人丁香五月综合激情,成人精品一区二区三区在线观看,东京热TOKYO综合久久精品,成人A级视频在线观看

您的瀏覽器版本過(guò)低,為保證更佳的瀏覽體驗,請點(diǎn)擊更新高版本瀏覽器

以后再說(shuō)X

歡迎訪(fǎng)問(wèn)瑞昌明盛自動(dòng)化設備有限公司網(wǎng)站!

圖片名

全國訂購熱線(xiàn):
+86 15270269218E-mail:xiamen2018@foxmail.com

ABB >>

A-B>>

GE>>

BENTLY>>

DEIF LSU-113DG

DEIF LSU-113DG

DEIF LSU-113DG負荷分配器,LSU-113DG如何使用增加設備故障。對于GMR PLC必須發(fā)出GMR輸入/輸出重置命令(%M12258)以恢復使用這些輸入通道。4.VersaMax GNIU的熱拆卸和熱插入不適用被允許嘗試熱插拔GNIU可能會(huì )導致干擾GNIU和其他設備之間的背板傳輸并且可能導致GNIU的診斷測試聲明錯誤。這可能會(huì )導致電站中的其他模塊被標記為故障,也可能導致整個(gè)輸入站下線(xiàn)...

  • 功能特性
  • 參數規格
  • 視頻
  • 應用案例
  • 下載

DEIF LSU-113DG

    DEIF LSU-113DG負荷分配器,LSU-113DG如何使用

    增加設備故障。對于GMR PLC必須發(fā)出GMR輸入/輸出重置命令(%M12258)以恢復使用這些輸入通道。4.VersaMax GNIU的熱拆卸和熱插入不適用被允許嘗試熱插拔GNIU可能會(huì )導致

    干擾GNIU和其他設備之間的背板傳輸并且可能導致GNIU的診斷測試聲明錯誤。這可能會(huì )導致電站中的其他模塊被標記為故障,也可能導致整個(gè)輸入站下線(xiàn)。對于需要安裝VersaMax GNIU的情況更換后,系統的操作程序必須要求操作員在嘗試之前切斷GNIU的電源修理

    LSU-113DG (1).jpg

    DEIF LSU-113DG負荷分配器5、關(guān)閉整個(gè)VersaMax工作站將導致系統暫時(shí)失去該站中的所有模擬通道(最多60個(gè)),而不是僅與正在更換的模塊相關(guān)的通道。如果冗余VersaMax輸入站可用,則程序可以選擇允許整個(gè)系統繼續運行短時(shí)間內輸入通道冗余的降級水平正在修復出現故障的輸入站。

    操作說(shuō)明:概述1、在智能輸入/輸出模塊上執行固件升級時(shí)在Genius NIU站,主機控制器必須處于停機狀態(tài)模式,或者必須從NIU上卸下Genius網(wǎng)絡(luò )電纜。

      報錯 筆記拼

    Addition of Device fault. For the case of a GMR PLC, an operator
    must issue a GMR I/O Reset command (%M12258) to recover the
    use of those input channels.
    4. Hot Removal and Hot Insertion of the VersaMax GNIU is not
    permitted. Attempting to hot insert or hot remove the GNIU may
    interfere with backplane transfers between the GNIU and other
    modules in the station, and can cause the GNIU’s diagnostic tests
    to declare an error. That can cause other modules in the station to
    be marked as faulted, and may also cause the entire input station to
    go offline. For cases where a VersaMax GNIU needs to be
    replaced, the system’s operating procedures must require the
    operator to remove power from the GNIU before attempting the
    repair.
    5. Powering down the entire VersaMax station will cause the system
    to temporarily lose all analog channels (up to 60) in that station, not
    just the channels associated with the module that is being replaced.
    If a redundant VersaMax Input Station is available, the procedures
    may optionally allow the overall system to continue to operate with
    a degraded level of input channel redundancy for a short time while
    the faulted input station is being repaired.
    Operating Notes: General
    1. When performing a firmware upgrade on an intelligent I/O module
    in the Genius NIU station, the host controller must be put into Stop
    mode, or the Genius network cable must be removed from the NIU.


    品牌:DEIF

    型號:LSU-113DG

    產(chǎn)地:丹麥

    質(zhì)保:365天

    成色:全新/二手

    發(fā)貨方式:快遞發(fā)貨


圖片名 客服

在線(xiàn)客服 客服一號