婷婷成人丁香五月综合激情,成人精品一区二区三区在线观看,东京热TOKYO综合久久精品,成人A级视频在线观看

您的瀏覽器版本過(guò)低,為保證更佳的瀏覽體驗,請點(diǎn)擊更新高版本瀏覽器

以后再說(shuō)X

歡迎訪(fǎng)問(wèn)瑞昌明盛自動(dòng)化設備有限公司網(wǎng)站!

圖片名

全國訂購熱線(xiàn):
+86 15270269218E-mail:xiamen2018@foxmail.com

ABB >>

A-B>>

GE>>

BENTLY>>

BENTLY 125388-01H

BENTLY 125388-01H

BENTLY 125388-01H速度監測器嘗試通過(guò)以下方式將程序員連接到RX7i以太網(wǎng)將不成功。正常連接重試對話(huà)框不會(huì )顯示。重新啟動(dòng)運行程序員的計算機將解決該行為。在一個(gè)系統中,如果硬件配置是從一個(gè)目標存儲的,則不要使用多個(gè)目標目標和邏輯從另一個(gè)目標存儲,通過(guò)閃存通電不起作用。觀(guān)察到的行為是flash,機器版軟件報告硬件配置和邏輯“不平等”。下載具有非常大的硬件配置或如果使用大量用戶(hù)內存,則可能...

  • 功能特性
  • 參數規格
  • 視頻
  • 應用案例
  • 下載

BENTLY 125388-01H

    BENTLY 125388-01H速度監測器

    嘗試通過(guò)以下方式將程序員連接到RX7i以太網(wǎng)將不成功。正常連接重試對話(huà)框不會(huì )顯示。重新啟動(dòng)運行程序員的計算機將解決該行為。在一個(gè)系統中,如果硬件配置是從一個(gè)目標存儲的,則不要使用多個(gè)目標目標和邏輯從另一個(gè)目標存儲,通過(guò)閃存通電不起作用。觀(guān)察到的行為是flash,機器版軟件報告硬件配置和邏輯“不平等”。下載具有非常大的硬件配置或如果使用大量用戶(hù)內存,則可能會(huì )遇到將配置寫(xiě)入閃存時(shí)出現“序列存儲失敗”錯誤。要解決此錯誤,可以執行以下任一操作或兩個(gè)操作:有幫助:

    125388-01H -2.jpg

    BENTLY 125388-01H速度監測器1、在執行寫(xiě)入之前,執行明確的清除閃存。

    2、增加機器版軟件使用的操作超時(shí)在執行寫(xiě)入之前。這是通過(guò)擴展目標檢查器窗口中的其他配置控制器,并調整請求超時(shí)。超時(shí)可能會(huì )需要增加到60000毫秒,具體取決于使用的內存量和閃存的狀況在一些斷電事件后,霍納熱電偶模塊(HE697THM160)可能無(wú)法成功通電。失敗后,%AI數據將無(wú)法正確更新,并將繼續返回零值。此事件沒(méi)有模塊故障指示燈。用戶(hù)應該再次通電以恢復正常功能。擴展機架中模塊上的故障觸點(diǎn)當擴展機架通電時(shí),插槽故障觸點(diǎn)將過(guò)早地表明擴展機架中的模塊沒(méi)有在完成通電之前出現故障。使用輸入/輸出點(diǎn)故障觸點(diǎn)驗證輸入/輸出的有效性。如果90-70系列遠程輸入/輸出站和其中一個(gè)存在多個(gè)故障,則遠程輸入/輸出站上的故障觸點(diǎn)故障觸點(diǎn)使用遠程輸入/輸出站的模塊參考將錯誤地指示遠程輸入/輸出站。

    BIT\u SEQ function block DIR參數BIT\u SEQ function block應要求用戶(hù)流動(dòng)布爾值邏輯轉換為DIR參數,但目前沒(méi)有。如果沒(méi)有DIR參數如果存在,則默認情況下,BIT_SEQ將遞增。

    WinLoader可能會(huì )停止在運行Windows 2000并使用某些版本的Symantec防病毒保護,如果在advanced中使用,WinLoader將失敗模式恢復需要循環(huán)計算機電源。

    Infrequently, an attempt to connect a programmer to an RX7i via

    Ethernet will be unsuccessful. The normal connection retry dialog will not

    be displayed. Rebooting the computer that is running the programmer

    will resolve the behavior.

    Don’t use multiple targets In a system in which the hardware configuration is stored from one

    target and logic is stored from a different target, powering-up from flash

    will not work. The observed behavior is that, following a power up from

    flash, Machine Edition software reports hardware configuration and logic

    "not equal".

    Sequence store failure When downloading projects with very large hardware configuration or

    which use large amounts of user memory, it is possible to encounter a

    “Sequence Store Failure” error when writing the configuration to flash.

    To work around this error, either or both of the following actions may be

    helpful:

    1. Perform an explicit clear of flash prior to performing the write.

    2. Increase the operation timeout used by Machine Edition software

    prior to performing the write. This is done by expanding the

    Additional Configuration in the Inspector window for the target

    controller, and adjusting the Request Timeout. The timeout may

    need to be increased to as much as 60000 msec, depending on

    the amount of memory used and the condition of the flash memoryfter some power loss events, the Horner Thermocouple module

    (HE697THM160) may fail to power up successfully. After failure, the %AI

    data will not be updated correctly and will continue to return zero values.

    There are no module fault indicators for this event. The user should

    power cycle again to restore normal function.

    Fault contacts on modules in expansion rack When an expansion rack powers up, the slot fault contacts will

    prematurely indicate that the modules in the expansion rack are not

    faulted before they complete their power up. Use I/O point fault contacts

    to verify validity of the I/O.

    Fault contacts on Remote I/O Station If multiple faults exist in a Series 90-70 Remote I/O Station and one of

    them is corrected, a FAULT contact that uses the Remote I/O Station’s

    module reference will incorrectly indicate that no faults exist at the

    Remote I/O Station.

    BIT_SEQ function block DIR parameter The BIT_SEQ Function Block should require the user to flow BOOLEAN

    logic into the DIR parameter, but currently does not. If no DIR parameter

    is present, the BIT_SEQ will increment by default.

    WinLoader may stop operating On computers running Windows 2000 and using some versions of

    Symantec Antivirus protection, WinLoader will fail if used in advanced

    mode. Recovery requires cycling the computer's power. 


    品牌:BENTLY

    型號:125388-01H

    產(chǎn)地:美國

    質(zhì)保:365天

    成色:全新/二手

    發(fā)貨方式:快遞發(fā)貨


圖片名 客服

在線(xiàn)客服 客服一號