婷婷成人丁香五月综合激情,成人精品一区二区三区在线观看,东京热TOKYO综合久久精品,成人A级视频在线观看

您的瀏覽器版本過(guò)低,為保證更佳的瀏覽體驗,請點(diǎn)擊更新高版本瀏覽器

以后再說(shuō)X

歡迎訪(fǎng)問(wèn)瑞昌明盛自動(dòng)化設備有限公司網(wǎng)站!

圖片名

全國訂購熱線(xiàn):
+86 15270269218E-mail:xiamen2018@foxmail.com

ABB >>

A-B>>

GE>>

BENTLY>>

4301-MBP-DFCM

4301-MBP-DFCM

主營(yíng)產(chǎn)品PLC可編程控制器模塊,DCS卡件,ESD系統卡件,振動(dòng)監測系統卡件,汽輪機控制系統模塊,燃氣發(fā)電機備件等,優(yōu)勢品牌:Allen Bradley、BentlyNevada、ABB、Emerson Ovation、Honeywell DCS、Rockwell ICS Triplex、FOXBORO、Schneider PLC、GE Fanuc、Motorola、HIMA、TRICONEX、P...

  • 功能特性
  • 參數規格
  • 視頻
  • 應用案例
  • 下載

4301-MBP-DFCM

    主營(yíng)產(chǎn)品

    PLC可編程控制器模塊,DCS卡件,ESD系統卡件,振動(dòng)監測系統卡件,汽輪機控制系統模塊,燃氣發(fā)電機備件等,優(yōu)勢品牌:Allen Bradley、BentlyNevada、ABB、Emerson Ovation、Honeywell DCS、Rockwell ICS Triplex、FOXBORO、Schneider PLC、GE Fanuc、Motorola、HIMA、TRICONEX、Prosoft等各種進(jìn)口工業(yè)零部件

    產(chǎn)品廣泛應用于冶金、石油天然氣、玻璃制造業(yè)、鋁業(yè)、石油化工、煤礦、造紙印刷、紡織印染、機械、電子制造、汽車(chē)制造、塑膠機械、電力、水利、水處理/環(huán)保、鍋爐供暖、能源、輸配電等等

    PROSOFT 4301-MBP-DFCM總線(xiàn)模塊

    驅動(dòng)控制器控制電機保持制動(dòng)器。只要這個(gè)控制器制造商不提供功能。必須:使用外部設備。在這種情況下,連接外部制動(dòng)電壓直接連接到電機上的制動(dòng)器接頭BR+和BR-并且使用外部電路來(lái)切換它們。使用ADP電機時(shí),溫度傳感器電纜可以:不連接到X6。應使用750R電阻器連接在X6.1和X6.2之間。

    對于A(yíng)DP電機,溫度信號通過(guò)電機電纜僅用于控制器。

    注:如果使用電機保持制動(dòng)器,則必須連接外部24V三相電壓源。

    本項目中列出了抱閘的電流消耗交流電機規劃手冊。注意:內部制動(dòng)控制開(kāi)關(guān)只能提供2A

    最大限度交流電機保持制動(dòng)器不是工作制動(dòng)器。之后它會(huì )慢慢消失關(guān)閉制動(dòng)器時(shí)電機旋轉約20000轉。

    注:要釋放MHP交流伺服電機中的保持制動(dòng)器,應用直流+24V+/-10%直接連接至電機。電壓釋放制動(dòng)器必須應用于X6/3(+24V)和X6/6(0V)或直接連接到電機。

    必須確保制動(dòng)器

    即使使用更長(cháng)的電機電源線(xiàn),也會(huì )釋放(長(cháng)電機電源電纜的電壓降可能為:通過(guò)增加電源電壓(高達DC+26.5V)進(jìn)行補償和/或在X6/3和X6/6處具有穩壓電源)。

    XS1,電機電纜屏蔽附件

    使用將整個(gè)電機電纜屏蔽放置在屏蔽支架XS1上提供的剪輯。通過(guò)選擇適當的將支架卡在安裝板上。電纜的輸出方向可以垂直或水平,可通過(guò)移動(dòng)進(jìn)行選擇和設置根據需要安裝面板。t1:取決于驅動(dòng)器的參數化功能

    t2:取決于PLC的反應時(shí)間以下值適用于10 mF的最大附加電容:或20mF!

    t3:裝置中K1主接觸器的接通延遲(最大3.6 ms*1)

    t4:建立直流母線(xiàn)電壓的時(shí)間(最大4.1s*1)

    圖7-26:裝置通電時(shí)的時(shí)間順序

    The drive controller controls the motor holding brake. As long as this

    function is not available from the control manufacturer it is necessary to

    use an external device. In this case, connect the external brake voltage

    directly to the brake connections BR+ and BR- which are on the motor

    and switch these using an external circuit.When using ADP motors the temperature sensor cable can

    not be connected to X6. Instead a 750R resistor should be

    connected between X6.1 and X6.2.

    With ADP motors the temperature signal transmitted via the

    motor cable is only used in the controller.

    Note: If a motor holding brake is used, then it is necessary to

    connect an external 24V three-phase voltage source.

    The current consumption of the holding brake is listed in the project

    planning manual of AC motors.

    Note: The internal brake control switch can only supply 2A

    maximum.

    The AC motor holding brake is not a working brake. It wears down after

    about 20,000 motor revolutions against the closed brake.

    Note: To release a holding brake in an MHP AC servo motor, apply

    the DC +24V +/- 10 % directly to the motor. The voltage to

    release the brake must either applied to X6/3 (+24V) and X6/6

    (0V) or directly to the motor. It must be ensured that the brake

    will release even if longer motor power cables are used

    (voltage drop with long motor power cables can be

    compensated by increasing supply voltage (up to DC +26.5V)

    and/or with a regulated voltage supply at X6/3 and X6/6).

    XS1, shield attachment for motor cable

    The entire motor cable shield is placed on shield bracket XS1 using the

    supplied clips. The cable diameter is matched by selecting an appropriate

    clip bracket on the mounting panel. The output direction of the cable can

    be either vertical or horizontal and this can be selected and set by moving

    the mounting panel as needed.t1: depends on parametrized function of the drives

    t2: depends on the reaction time of the PLC

    The following values are valid for a maximum additional capacitance of 10 mF

    or 20 mF respectively!

    t3: on-delay of K1 mains contactor in the unit (max. 3,6 ms *1)

    t4: time to build up DC bus voltage (max. 4,1 s *1)

    Fig. 7-26: Chronological sequence when powering unit up

    品牌:PROSOFT

    型號:4301-MBP-DFCM

    產(chǎn)地:美國

    質(zhì)保:365天

    成色:全新/二手

    發(fā)貨方式:快遞發(fā)貨


圖片名 客服

在線(xiàn)客服 客服一號