CSI3120

CSI3120振動(dòng)變送器恢復出廠(chǎng)變量參數:要恢復原始出廠(chǎng)變量參數,請拉在“配置”菜單下,選擇“電機”,然后選擇電機族和電機型號。點(diǎn)擊“至驅動(dòng)”按鈕將變量參數發(fā)送到RAM和“RAM/E2“保存”按鈕保存到EEPROM?;謴妥远x變量參數:此過(guò)程假設您保存了自定義變量參數設置為.SSV文件,如上所述。要恢復自定義參數,請下拉編輯菜單中,選擇備份變量,然后單擊“打開(kāi)”。突出顯示要導入變量的自定義.SSV...

  • 功能特性
  • 參數規格
  • 視頻
  • 應用案例
  • 下載

CSI3120

    微信圖片_20220909170353.jpg

    CSI3120振動(dòng)變送器

    恢復出廠(chǎng)變量參數:要恢復原始出廠(chǎng)變量參數,請拉在“配置”菜單下,選擇“電機”,然后選擇電機族和電機型號。點(diǎn)擊“至驅動(dòng)”按鈕將變量參數發(fā)送到RAM和“RAM/E2

    “保存”按鈕保存到EEPROM。

    恢復自定義變量參數:此過(guò)程假設您保存了自定義變量

    參數設置為.SSV文件,如上所述。要恢復自定義參數,請下拉編輯

    菜單中,選擇備份變量,然后單擊“打開(kāi)”。突出顯示要導入變量的自定義.SSV文件

    參數輸入編輯器。單擊“Xmit”將變量參數發(fā)送到驅動(dòng)器。

    終端模式

    使用MOTIONLINK終端模式(或任何其他“啞”主機)直接監控或修改

    變量設置和命令驅動(dòng)器。這種方法僅適用于帶有Windows的PC操作系統不可用和/或您熟悉變量和命令集。

    每個(gè)變量和命令都引用其語(yǔ)法和參數定義。變量和命令按字母順序分組,便于查找,并在本手冊末尾找到。確信在開(kāi)始之前,請查看此信息。

    初始啟動(dòng)

    大多數驅動(dòng)器出廠(chǎng)時(shí)已為特定電機配置。你可以證實(shí)這一點(diǎn)

    通過(guò)施加邏輯電源并監控狀態(tài)顯示。工廠(chǎng)配置的驅動(dòng)器通過(guò)

    通電順序:在穩定到指示

    操作模式。如果驅動(dòng)器未配置特定電機,顯示屏將閃爍負號符號“-”,表示必須輸入驅動(dòng)器、電機和應用程序變量參數。其余的本節的介紹了設置未配置驅動(dòng)器的過(guò)程。

    向驅動(dòng)器通電時(shí)必須小心。工廠(chǎng)配置為:通電后啟用。

    驗證硬件遠程啟用

    (遠程)啟用開(kāi)關(guān)被禁用。

    通電后,伺服星執行一系列自檢。如果狀態(tài)顯示點(diǎn)亮,則實(shí)數,則未發(fā)現錯誤,EEPROM已加載其可變參數(或已加載在EEPROM數據無(wú)效的情況下具有默認值)輸入RAM。I/O上的遠程啟用開(kāi)關(guān)

    連接器(C3)現在可以通電,從而啟用伺服回路。驅動(dòng)啟用邏輯基于以下變量開(kāi)關(guān)和標志:

    激活:這是指示驅動(dòng)器啟用/禁用狀態(tài)的總體就緒標志。如果高(1) ,驅動(dòng)器已啟用,電機正在通電。下式必須為真才能使活動(dòng)變高:活動(dòng)=(就緒)和(遠程)

    其中就緒=(DRIVEOK)和(SWEN)

    就緒:表示驅動(dòng)器無(wú)故障且已準備好硬件啟用的標志。

    DRIVEOK(驅動(dòng)器正常):開(kāi)關(guān)指示驅動(dòng)器故障的狀態(tài)。

    SWEN:開(kāi)關(guān)指示軟件啟用狀態(tài)(EN或DIS)。

    遠程:開(kāi)關(guān)指示C3連接器上硬件遠程啟用線(xiàn)路的狀態(tài)。

    Restoring Factory Variable Parameters: To restore the original factory variable parameters, pull down the Configure menu, select Motor, and select the motor family and motor model. Click the “To Drive” button to send the variable parameters to RAM and the “RAM/E2 SAVE” button to save to EEPROM. Restoring Custom Variable Parameters: This process assumes that you saved the custom variable parameters to a .SSV file, as described above. To restore the custom parameters, pull down the Edit menu, select Backup Variables, and click on “Open”. Highlight the custom .SSV file to import variable parameters into editor. Click “Xmit” to send variable parameters to drive. Terminal Mode Use the MOTIONLINK Terminal Mode (or any other “dumb” host) to directly monitor or modify the variable set and command the drive. This approach should only be taken when a PC with a Windows operating system is not available and/or you are well-versed with the variable and command set. Each variable and command are referenced for its syntax and parameter definition. The variables and commands are grouped alphabetically for easy look-up and are found at the end of this manual. Be sure you review this information before you begin. Initial Startup Most drives are shipped from the factory already configured for a particular motor. You can verify this by applying logic power and monitoring the Status Display. A factory-configured drive goes through a power-up sequence flashing all segments of the display before settling out to a number indicating the mode of operation. If the drive is not configured with a particular motor, the display will flash a minus sign "-", indicating that you must enter drive, motor, and application variable parameters. The remainder of this section describes the process of setting up a non-configured drive. Caution must be taken when applying power to the drive. It is factory-configured to enable upon application of power. Verify that the hardware Remote Enable (REMOTE) enable switch is disabled. Upon powering up, the SERVOSTAR performs a series of self-tests. If the Status Display illuminates a solid number, then no errors were found and the EEPROM has loaded its variable parameters (or loaded with default values in case of invalid EEPROM data) into RAM. The Remote Enable switch on the I/O connector (C3) may now be energized, thus enabling the servo loops.