婷婷成人丁香五月综合激情,成人精品一区二区三区在线观看,东京热TOKYO综合久久精品,成人A级视频在线观看

您的瀏覽器版本過(guò)低,為保證更佳的瀏覽體驗,請點(diǎn)擊更新高版本瀏覽器

以后再說(shuō)X

歡迎訪(fǎng)問(wèn)瑞昌明盛自動(dòng)化設備有限公司網(wǎng)站!

圖片名

全國訂購熱線(xiàn):
+86 15270269218E-mail:xiamen2018@foxmail.com

ABB >>

A-B>>

GE>>

BENTLY>>

REXROTH R900955334伺服驅動(dòng)模塊

REXROTH R900955334伺服驅動(dòng)模塊

公司主營(yíng)產(chǎn)品圖展示產(chǎn)品優(yōu)勢1:國外專(zhuān)業(yè)的供貨渠道,具有價(jià)格優(yōu)勢2:產(chǎn)品質(zhì)量保證,讓您售后無(wú)憂(yōu)3:全國快遞包郵產(chǎn)品詳情介紹REXROTH R900955334伺服驅動(dòng)模塊本章提供了有關(guān)配置XVME-660模塊的信息。它還提供了有關(guān)將XVME-660安裝到背板中以及啟用以太網(wǎng)控制器。圖2-1顯示了XVME-660主板。開(kāi)關(guān)設置XVME-660在主板上有一個(gè)四極開(kāi)關(guān)(SW1)(見(jiàn)圖2-1)。這個(gè)開(kāi)關(guān)功能...

  • 功能特性
  • 參數規格
  • 視頻
  • 應用案例
  • 下載

REXROTH R900955334伺服驅動(dòng)模塊

    公司主營(yíng)產(chǎn)品圖展示

    微信圖片_20220913175441.jpg

    產(chǎn)品優(yōu)勢

    1:國外專(zhuān)業(yè)的供貨渠道,具有價(jià)格優(yōu)勢

    2:產(chǎn)品質(zhì)量保證,讓您售后無(wú)憂(yōu)

    3:全國快遞包郵

    產(chǎn)品詳情介紹

    REXROTH R900955334伺服驅動(dòng)模塊

    本章提供了有關(guān)配置XVME-660模塊的信息。它還提供了有關(guān)將XVME-660安裝到背板中以及啟用以太網(wǎng)控制器。圖2-1顯示了XVME-660主板。開(kāi)關(guān)設置XVME-660在主板上有一個(gè)四極開(kāi)關(guān)(SW1)(見(jiàn)圖2-1)。這個(gè)開(kāi)關(guān)功能如表2-3所示。該開(kāi)關(guān)控制系統響應至前面板中止開(kāi)關(guān)(SW2)。表2-4顯示了所需的開(kāi)關(guān)設置在XVME-660 CPU上重置,僅重置VME背板,或重置兩者。這個(gè)開(kāi)關(guān)3保留,應始終閉合。XVME-660隨附:四個(gè)開(kāi)關(guān)處于閉合位置(這導致SW2重置XVME-660和VME背板)。前板50針I(yè)P連接器(P6)接收IP模塊的I/O并連接線(xiàn)路通過(guò)線(xiàn)路連接至前面板50針I(yè)P連接器(P9)。這些線(xiàn)路上的信號取決于特定的工業(yè)組件模塊。請參閱Industry Pack模塊文檔,了解更多信息。

    1.斷開(kāi)背板和卡固定框架的所有電源。斷開(kāi)電力電纜。

    2.確保底板連接器P1和P2可用。

    3.驗證所有跳線(xiàn)設置是否正確。

    4.驗證板卡固定架插槽是否清晰且可接近。

    5.將XVME-660安裝在卡籠中,方法是將裝置置于塑料導軌的中心

    插槽(P1連接器朝上)。將板慢慢推向機箱后部,直到P1和P2連接器接合。板應在塑料中自由滑動(dòng)指南。

    不要使用過(guò)大的力或壓力接合接頭。如果板與背板連接不正確,請卸下模塊并檢查所有連接器和導槽是否損壞或堵塞。

    6.擰緊電路板頂部和底部的機器螺釘,將模塊固定至機箱。

    7.如表2-26所示,通過(guò)將每個(gè)接口電纜連接到XVME-660板正面的適當連接器,連接所有剩余外圍設備。

    8.打開(kāi)VMEbus卡固定框架的電源。加載SCSI驅動(dòng)程序

    要啟用SCSI控制器,必須從隨附的文檔和支持庫CD中加載適用于操作系統的SCSI驅動(dòng)程序XVME-660。

    啟用XVME-660 SCSI引導功能

    要啟用SCSI引導功能,請執行以下步驟:

    1.重置XVME-660。

    2.當內存測試開(kāi)始時(shí),按F2鍵進(jìn)入BIOS設置菜單。(另見(jiàn)有關(guān)訪(fǎng)問(wèn)BIOS設置菜單的信息,請參閱第3章。)

    3.選擇高級菜單,然后選擇PCI配置子菜單,再選擇子SCSI PCI子菜單。

    4.確保選項ROM掃描字段已啟用。

    5.保存更改并退出BIOS設置菜單。

    6.重新啟動(dòng)X(jué)VME-660。

    This chapter provides information on configuring the XVME-660 modules. It also provides information on installing the XVME-660 into a backplane and enabling the

    Ethernet controller. Figure 2-1 shows the jumper, switch, and connector locations on the

    XVME-660 mainboard. Switch Settings

    The XVME-660 has one four-pole switch (SW1) on the mainboard (see Figure 2-1). The

    switches functions are explained in Table 2-3. This switch controls the system response

    to the front panel Abort switch (SW2). Table 2-4 shows the switch settings required to

    reset on the XVME-660 CPU, to reset only the VME backplane, or to reset both. The

    switch 3 is reserved and should always be closed. The XVME-660 is shipped with all

    four switches in the closed position (which causes SW2 to reset both the XVME-660 and

    the VME backplane). The front board 50-pin IP connector (P6) takes the I/O of the IP module and connects line

    by line to the front panel 50-pin IP connector (P9). The signals on these lines are dependent on the particular Industry Pack module. See Industry Pack module documentation for

    more information. 1. Disconnect all power supplies to the backplane and the card cage. Disconnect the

    power cable.

    2. Make sure backplane connectors P1 and P2 are available.

    3. Verify that all jumper settings are correct.

    4. Verify that the card cage slot is clear and accessible.

    5. Install the XVME-660 in the card cage by centering the unit on the plastic guides in

    the slots (P1 connector facing up). Push the board slowly toward the rear of the chassis until the P1 and P2 connectors engage. The board should slide freely in the plastic

    guides.

    Do not use excessive force or pressure to engage the connectors. If the

    boards do not properly connect with the backplane, remove the module

    and inspect all connectors and guide slots for damage or obstructions.

    6. Secure the module to the chassis by tightening the machine screws at the top and bottom of the board.

    7. Connect all remaining peripherals by attaching each interface cable into the appropriate connector on the front of the XVME-660 board as shown in Table 2-26.

    8. Turn on power to the VMEbus card cage. Loading the SCSI Driver

    To enable the SCSI controller, you must load the applicable SCSI driver for your operating system from the Documentation and Support Library CD included with the

    XVME-660.

    Enabling the XVME-660 SCSI Boot Capabilities

    To enable SCSI boot capabilities perform the following steps:

    1. Reset the XVME-660.

    2. When the memory test starts, press F2 to enter the BIOS Setup Menu. (Also see

    Chapter 3 for information on accessing the BIOS setup menus.)

    3. Select the Advanced menu, then the PCI Configuration submenu, and then the Daughter SCSI PCI submenu.

    4. Make sure that the Option ROM Scan field is Enabled.

    5. Save the changes and exit the BIOS Setup menu.

    6. Restart the XVME-660.

    品牌:REXROTH

    型號:R900955334

    產(chǎn)地:美國

    質(zhì)保:365天

    成色:全新/二手

    發(fā)貨方式:快遞發(fā)貨


圖片名 客服

在線(xiàn)客服 客服一號