產(chǎn)品內容介紹
1394C-AM50-IH交流伺服控制器軸模塊
標準模式(所有電源模塊通用)z瞬時(shí)電源故障檢測-即使電源瞬時(shí)故障持續時(shí)間不超過(guò)20毫秒(未檢測到的瞬時(shí)電源故障),系統仍會(huì )繼續運行而不會(huì )中斷如果發(fā)生超過(guò)20毫秒的電源故障,控制器可能會(huì )也可能不會(huì )識別瞬時(shí)電源故障情況,因為存在不確定性。當控制器檢測到瞬時(shí)電源故障時(shí),它會(huì )暫停程序執行,同時(shí)保持其輸出的當前狀態(tài)。它還將瞬時(shí)電源故障發(fā)生的日期和時(shí)間記錄到CPU的錯誤日志文件中。當電源恢復時(shí),控制器恢復程序的執行。z電源故障檢測當CPU工作電壓(+5V)低于額定電壓的95%時(shí),控制器停止運行,關(guān)閉輸出,然后打開(kāi)故障觸點(diǎn)。(關(guān)于FAIL觸點(diǎn)如何工作的詳細信息,請參閱第A(yíng)2.3節)。z自動(dòng)恢復當電源從瞬時(shí)電源故障狀態(tài)恢復,CPU工作電壓(+5V)上升到額定電壓的95%以上時(shí),控制器自動(dòng)恢復正常操作。檢測到電源故障后,控制器以重置重新啟動(dòng)模式重新啟動(dòng)。
即時(shí)檢測模式
(當使用F3PU10-0N、F3PU10-10S、F3PU20-0N、F3PU20-0S、F3PU30-0N或F3PU30-0S時(shí))z瞬時(shí)電源故障檢測-即使電源瞬時(shí)故障持續時(shí)間不超過(guò)10ms(未檢測到的瞬時(shí)電源故障),系統仍會(huì )繼續運行,不會(huì )中斷如果發(fā)生超過(guò)10 ms小于25 ms的電源故障,控制器可能會(huì )識別或不識別瞬時(shí)電源故障情況,因為存在不確定性。當控制器檢測到瞬時(shí)電源故障時(shí),它保持或重置其輸出(根據停止時(shí)設置的輸出),暫停程序執行,然后打開(kāi)FAIL觸點(diǎn)。(有關(guān)FAIL觸點(diǎn)工作原理的詳細信息,請參閱本手冊第A(yíng)2.3節)。它還將瞬時(shí)電源故障發(fā)生的日期和時(shí)間記錄到CPU的錯誤日志文件中。檢測到瞬時(shí)電源故障后,控制器以重置重啟模式重新啟動(dòng)控制器始終檢測任何超過(guò)25毫秒的瞬時(shí)功率損失情況。z電源故障檢測當CPU工作電壓(+5V)低于額定電壓的95%時(shí),控制器的整個(gè)功能被禁用。z自動(dòng)恢復當電源從瞬時(shí)電源故障狀態(tài)恢復,CPU工作電壓(+5V)上升到額定電壓的95%以上時(shí),控制器自動(dòng)恢復正常操作。檢測到電源故障后,控制器以重置重啟模式重新啟動(dòng)。
Standard Mode (common to all power supply modules)
z Momentary Power Failure Detection - System operation continues without interruption even if the power fails momentarily for no longer than 20 ms (undetected momentary power failure). - If a power failure longer than 20 ms occurs, the controller may or may not recognize a momentary power failure condition because an uncertainty is involved. When the controller detects a momentary power failure, it suspends program execution while retaining the current state of its outputs. It also records the date and time at which the momentary power failure occurred into the error log file in the CPU. When power is restored, the controller resumes the execution of the program. z Power Failure Detection When the CPU operating voltage (+5V) falls below 95% of the rated voltage, the controller stops operation, turns off its outputs, and then turn on the FAIL contact. (Refer to Section A2.3 for details on how the FAIL contact works). z Automatic Recovery The controller resumes normal operation automatically when the power recovers from a momentary power failure condition and the CPU operating voltage (+5V) rises above 95% of the rated voltage. The controller restarts in the reset restart mode after a power failure is detected.
Immediate Detection Mode
(when F3PU10-0N, F3PU10-0S, F3PU20-0N, F3PU20-0S, F3PU30-0N or F3PU30-0S is used) z Momentary Power Failure Detection - System operation continues without interruption even if the power fails momentarily for no longer than 10 ms (undetected momentary power failure). - If a power failure longer than 10 ms and less than 25 ms occurs, the controller may or may not recognize a momentary power failure condition because an uncertainty is involved. When the controller detects a momentary power failure, it holds or resets its outputs (in accordance with the output set at stop) , it suspends program execution, and then it turns on the FAIL contact. (Refer to Section A2.3 of this manual for details on how the FAIL contact works). It also records the date and time at which the momentary power failure occurred into the error log file in the CPU. The controller restarts in the reset restart mode after a momentary power failure is detected. - The controller always detects any momentary power loss conditions that are longer than 25 ms. z Power Failure Detection The entire functionality of the controller is disabled when the CPU operating voltage (+5V) falls below 95% of the rated voltage. z Automatic Recovery The controller resumes normal operation automatically when the power recovers from a momentary power failure condition and the CPU operating voltage (+5V) rises above 95% of the rated voltage. The controller restarts in the reset restart mode following the detection of a power failure condition.
公司主營(yíng)產(chǎn)品圖展示
產(chǎn)品優(yōu)勢
1:國外專(zhuān)業(yè)的供貨渠道,具有價(jià)格優(yōu)勢
2:產(chǎn)品質(zhì)量保證,讓您售后無(wú)憂(yōu)
3:全國快遞包郵
4:一對一服務(wù)
公司主營(yíng)范圍簡(jiǎn)介
PLC可編程控制器模塊,DCS卡件,ESD系統卡件,振動(dòng)監測系統卡件,汽輪機控制系統模塊,燃氣發(fā)電機備件等,優(yōu)勢品牌:Allen Bradley、BentlyNevada、ABB、Emerson Ovation、Honeywell DCS、Rockwell ICS Triplex、FOXBORO、Schneider PLC、GE Fanuc、Motorola、HIMA、TRICONEX、Prosoft等各種進(jìn)口工業(yè)零部件、歐美進(jìn)口模塊。
產(chǎn)品廣泛應用于冶金、石油天然氣、玻璃制造業(yè)、鋁業(yè)、石油化工、煤礦、造紙印刷、紡織印染、機械、電子制造、汽車(chē)制造、塑膠機械、電力、水利、水處理/環(huán)保、鍋爐供暖、能源、輸配電等等