TRICONEX 9671-810工控模塊備件
伺服電機
旋轉變壓器和高分辨率電機的電機速度扭矩曲線(xiàn)重要:所示曲線(xiàn)和性能數據適用于放大器額定值大于或等于電機持續失速電流的電機和組合。在環(huán)境中,在的線(xiàn)路電壓下測試電機。外殼溫度約為,電機繞組比環(huán)境溫度升高。當電機安裝在×鋼安裝支架上時(shí),確定扭矩額定值。電機包含兩個(gè)串聯(lián)的熱開(kāi)關(guān),在超溫條件下打開(kāi)。溫度設置為±。觸點(diǎn)的額定值為時(shí)為,時(shí)為。下面顯示的所有值的公差為±。類(lèi)別參數環(huán)境溫度單位一般連續失速扭矩額定輸出峰值失速扭矩。持續失速電流時(shí)的安培峰值失速電流下的安培時(shí)的機械時(shí)間常數時(shí)的電氣時(shí)間常數下的額定速度熱最高環(huán)境溫度無(wú)降額℃絕緣等級熱時(shí)間常數分鐘。
伏時(shí)的電壓常數
額定運行間歇運行額定轉速轉速扭矩電機峰值峰值續續峰值,系列,交流伺服電機出版物年月和旋轉變壓器和高分辨率電機的電機速度扭矩曲線(xiàn)重要:所示曲線(xiàn)和性能數據適用于放大器額定值大于或等于電機持續失速電流的電機和組合。在環(huán)境中,在的線(xiàn)路電壓下測試電機。外殼溫度約為,電機繞組比環(huán)境溫度升高。當電機安裝在×鋼安裝支架上時(shí),確定扭矩額定值。電機包含兩個(gè)串聯(lián)的熱開(kāi)關(guān),在超溫條件下打開(kāi)。
servo motor
Motor speed torque curves for resolvers and high-resolution motors are important: the curves and performance data shown are applicable to motors and combinations with amplifier ratings greater than or equal to the continuous stall current of the motor. In the environment, test the motor at line voltage of. The enclosure temperature is about, and the motor winding temperature is higher than the ambient temperature. When the motor is installed on the × Determine the torque rating when mounting on a steel bracket. The motor contains two thermal switches in series, which open under overtemperature conditions. The temperature is set to ±. The contact is rated when is and when is. All values shown below have a tolerance of ±. Category Parameter Ambient temperature unit: generally continuous stall torque, rated output peak stall torque. Ampere at continuous stall current, peak value at stall current, mechanical time constant at ampere hour, electrical time constant at rated speed, thermal maximum ambient temperature without derating, thermal time constant at insulation grade, minute.
Voltage constant at volts
Rated operation Intermittent operation Rated speed Speed Torque motor peak peak continuous peak, series, AC servo motor publications Year Month and motor speed torque curves for resolvers and high-resolution motors Important: The curves and performance data shown are applicable to motors and combinations with amplifier ratings greater than or equal to motor continuous stall current. In the environment, test the motor at line voltage of. The enclosure temperature is about, and the motor winding temperature is higher than the ambient temperature. When the motor is installed on the × Determine the torque rating when mounting on a steel bracket. The motor contains two thermal switches in series, which open under overtemperature conditions.