婷婷成人丁香五月综合激情,成人精品一区二区三区在线观看,东京热TOKYO综合久久精品,成人A级视频在线观看

您的瀏覽器版本過(guò)低,為保證更佳的瀏覽體驗,請點(diǎn)擊更新高版本瀏覽器

以后再說(shuō)X

歡迎訪(fǎng)問(wèn)瑞昌明盛自動(dòng)化設備有限公司網(wǎng)站!

圖片名

全國訂購熱線(xiàn):
+86 15270269218E-mail:xiamen2018@foxmail.com

ABB >>

A-B>>

GE>>

BENTLY>>

MVME-5100備件模塊

MVME-5100備件模塊

MVME-5100備件模塊 所選當前配置中未找到的DDCS/UDP設備不會(huì )顯示在兩個(gè)列表中。所以你只能在這里操縱找到的設備。OPC服務(wù)器驅動(dòng)窗口2 7-27現在您可以:?通過(guò)單擊>>按鈕添加所有找到的尚未包含的設備?通過(guò)單擊按鈕刪除所有找到的當前包含的設備。?通過(guò)在“包含”列表中單擊(按住Ctrl鍵或Shift鍵)并單擊>按鈕來(lái)選擇當前包含的選定設備,從而刪除這些設備。例如:OP...

  • 功能特性
  • 參數規格
  • 視頻
  • 應用案例
  • 下載

MVME-5100備件模塊

    MVME-5100備件模塊

     所選當前配置中未找到的DDCS/UDP設備不會(huì )顯示在兩個(gè)列表中。所以你只能在這里操縱找到的設備。OPC服務(wù)器驅動(dòng)窗口2 7-27現在您可以:?通過(guò)單擊>>按鈕添加所有找到的尚未包含的設備?通過(guò)單擊按鈕刪除所有找到的當前包含的設備。?通過(guò)在“包含”列表中單擊(按住Ctrl鍵或Shift鍵)并單擊>按鈕來(lái)選擇當前包含的選定設備,從而刪除這些設備。例如:OPC服務(wù)器7-28 DriveWindow 2最后單擊“確定”返回配置設置對話(huà)框?,F在可以在固定IP/遠程子網(wǎng)列表中看到更改。OPC服務(wù)器驅動(dòng)窗口2 7-29 7.1.11典型工作流當您來(lái)到一個(gè)以太網(wǎng)段中具有NETA-21設備且已配置為啟用DDCS網(wǎng)關(guān)的站點(diǎn)時(shí),您的工作流可能如下所述。第一件事是打開(kāi)NETA-21設備,等待3-5分鐘使其啟動(dòng)并運行。然后啟動(dòng)DriveWindow,但不要連接到OPC服務(wù)器。從網(wǎng)絡(luò )菜單的配置子菜單中選擇DDCS/UDP。從DDCS/UDP配置對話(huà)框的編輯菜單中選擇新建。OPC服務(wù)器7-30驅動(dòng)窗口2輸入新配置的名稱(chēng),您可以輕松地將其與站點(diǎn)關(guān)聯(lián),然后單擊確定。OPC服務(wù)器驅動(dòng)窗口2 7-31在新配置的設置對話(huà)框中啟用DDCS/UDP通信。使其他設置更改對該配置中的所有或許多DDCS/UDP設備通用(如節點(diǎn)號和DDCS/UDP裝置DDCS網(wǎng)絡(luò )中分支單元的存在)。不必手動(dòng)添加每個(gè)IP,可以通過(guò)單擊查找附近設備來(lái)添加它們。更改設置和添加IP地址的順序無(wú)關(guān)緊要。OPC服務(wù)器7-32 DriveWindow 2在“找到的設備”對話(huà)框中,選擇要使用新配置連接的設備。OPC服務(wù)器驅動(dòng)窗口2 7-33單擊確定。OPC服務(wù)器7-34驅動(dòng)窗口2如果DDCS/UDP設備需要與新配置的常用設置不同的特定設置,請右鍵單擊新配置設置對話(huà)框中固定IP/遠程子網(wǎng)列表中的IP地址,然后選擇屬性。也可以使用“編輯”菜單。更改您想要的設置(例如,使用特定的信道號,如果配置公用設置說(shuō)明通常沒(méi)有分支單元,則說(shuō)明此DDCS/UDP設備的DDCS網(wǎng)絡(luò )中存在或可能存在分支單元)。最后,單擊確定。OPC服務(wù)器驅動(dòng)窗口2 7-35在新配置設置對話(huà)框的設置中,完成后單擊確定。OPC服務(wù)器7-36 DriveWindow 2在DDCS/UDP配置對話(huà)框中,單擊確定以保存新配置并將其設置為當前配置。從網(wǎng)絡(luò )菜單中選擇網(wǎng)絡(luò )服務(wù)器(或按Ctrl+N)。

    Note that a DDCS/UDP device included in the selected Current configuration that is not found is not displayed in either of the lists. So you can manipulate here only the devices found. OPC Server DriveWindow 2 7-27 Now you can: ? Add all found devices not yet included by clicking the >> button ? Delete all found devices currently included by clicking the button. ? Delete selected devices currently included by selecting them by clicking (with Ctrl or Shift key down) in the Include list and then clicking the > button. For example: OPC Server 7-28 DriveWindow 2 Finally click OK to get back to the dialog box for Settings of a configuration. The changes can now be seen in the Fixed IPs / Remote Subnets list. OPC Server DriveWindow 2 7-29 7.1.11 Typical Workflow When you come to a site having NETA-21 devices in an Ethernet segment already configured to have the DDCS gateway enabled, your workflow may be as explained here. The first thing is to put the NETA-21 devices on and wait 3-5 minutes to get them up and running. Then start DriveWindow, but do not connect to an OPC Server. Select DDCS/UDP from Configure submenu of the Network menu. Select New from the Edit menu in the DDCS/UDP Configuration dialog box. OPC Server 7-30 DriveWindow 2 Enter a name for the new configuration that you can easily associate with the site and click OK. OPC Server DriveWindow 2 7-31 In the Settings for the new configuration dialog box enable DDCS/UDP Communication. Make other setting changes common for all or many of the DDCS/UDP devices in this configuration (like the node numbers and presence of a branching unit in the DDCS/UDP device DDCS network). Instead of adding each IP manually, they can be added by clicking Find Near Devices. The order of changing the settings and adding the IP addresses is immaterial. OPC Server 7-32 DriveWindow 2 In the Devices Found dialog box select the devices you want to connect to with the new configuration. OPC Server DriveWindow 2 7-33 Click OK. OPC Server 7-34 DriveWindow 2 If a DDCS/UDP device requires specific settings deviating from the common settings for the new configuration, right click its IP address in the Fixed IPs / Remote Subnets list in the Settings for the new configuration dialog box and select Properties. You can use the Edit menu as well. Change the settings you want to (like use a specific channel number and state that there is, or may be, a branching unit in the DDCS network of this DDCS/UDP device if the configuration common setting states that in general there a no branching units). Finally, click OK. OPC Server DriveWindow 2 7-35 In the settings for the new configuration Settings dialog box click OK when you are done. OPC Server 7-36 DriveWindow 2 In the DDCS/UDP Configuration dialog box click OK to save the new configuration and set it as Current configuration. Select Network Servers from the Network menu (or press Ctrl+N).

    GE SR489-P5-HI-A20-E.jpg

    23.jpg

    11.jpg

    3.jpg

    微信圖片_20220816092435.png



    品牌:  Motorola 

    型號:MVME-5100 

    產(chǎn)地:美國

    質(zhì)保:365天

    成色:全新/二手

    發(fā)貨方式:快遞發(fā)貨



圖片名 客服

在線(xiàn)客服 客服一號