MVME259D機器人備件
商標是其各自公司的財產(chǎn)。還可提供全系列兼容附件,包括:?饋線(xiàn)接線(xiàn)板和緊湊型母線(xiàn)?常開(kāi)和常閉前部和側面安裝的輔助觸點(diǎn)?并聯(lián)跳閘和欠壓跳閘輔助觸點(diǎn)?門(mén)耦合手柄?IP65外殼(UL/CSA類(lèi)型12)有關(guān)附件和規格的更多詳細信息,請參閱ab.com上的技術(shù)數據*所示馬力/kW額定值僅供參考。MPCB/MPSD的最終選擇取決于實(shí)際電機滿(mǎn)載電流。安裝說(shuō)明原始說(shuō)明VersaView 6300 DC連接器組件和更換安裝夾目錄號6300V-DCCONN、6300V-DCCONN2、6300V-DCCON3、,6300V-MTGCLIP16本出版物中的說(shuō)明適用于以下項目:?直流電源VersaView?6300 PC和VersaView 6300監視器的連接器組件?VersaView 630P面板PC和Versa View 6300M監視器的更換安裝夾安裝所需工具以下工具用于安裝6300V-DCCONN、6300V-DCCONN2、,或6300V-DCCONN3直流連接器組件:?帶公制平刃螺絲刀頭的可調扭矩螺絲刀?剝線(xiàn)器、切割器、,和壓接工具?剪切鉗?安全眼鏡以下工具用于安裝替換的6300V-MTGCLIP16安裝夾:?1.5 mm六角扳手(兩個(gè)隨安裝夾一起提供)?帶1.5 mm六方扳手頭的可調扭矩驅動(dòng)器?安全眼鏡安裝直流連接器組件連接器組件通過(guò)減少直流電源線(xiàn)移動(dòng)要組裝和連接連接器組件,請執行以下步驟。
1.斷開(kāi)計算機的電源。2.從計算機機箱上卸下直流接線(xiàn)板。3.打開(kāi)電腦附帶的電源連接器組裝套件(第3頁(yè)圖2中的A)。4.將電纜扎帶穿過(guò)相應連接器半部的插槽(第3頁(yè)圖2中的B)。5.剝開(kāi)每根直流電源線(xiàn)的末端,使其達到第2頁(yè)圖1所示的長(cháng)度。6.將每個(gè)剝開(kāi)的末端插入直流接線(xiàn)板,如圖1所述。主題頁(yè)安裝所需工具1安裝直流連接器組件1安裝更換安裝夾3重要的直流電源線(xiàn)必須為絞合銅,尺寸符合第2頁(yè)圖1。2羅克韋爾自動(dòng)化出版物6300V-IN003A-EN-P-2021 1月VersaView 6300直流連接器組件和更換安裝夾安裝說(shuō)明7。擰緊接線(xiàn)板頂部的螺釘,將直流電源線(xiàn)固定到圖1.8中的扭矩值。將連接器半體連同連接的系帶滑動(dòng)到直流接線(xiàn)板的端部(第3頁(yè)圖2中的C)。9.擰緊電纜扎帶,使其緊貼端子電線(xiàn)。10.使用切割鉗切割電纜扎帶的多余部分(第3頁(yè)圖2中的D)。11.安裝隨套件提供的白色標簽(第3頁(yè)圖2中的E)。12.對齊并安裝另一半連接器夾具,以完成組裝(第3頁(yè)圖2中的F)。13.將直流接線(xiàn)板與連接器組件重新連接到計算機機箱。將直流接線(xiàn)板法蘭螺釘擰緊至圖1.14中的值。打開(kāi)主電源開(kāi)關(guān)或斷路器。圖1-直流接線(xiàn)板連接規范白色標簽可用于標識或其他信息。正確安裝后,半卡箍的兩個(gè)凸舌將鎖定到位。項目描述屬性6300V-DCCONN 6200V-DCCONN2 6300V-DCCONN3 1 DC+(24V DC標稱(chēng))推薦電源線(xiàn)尺寸1.5 mm2(16 AWG)2.5 mm2(14 AWG)4 mm2(12 AWG)2 DC-(0V DC)
Trademarks are the property of their respective companies. A full range of compatible accessories are also available, including: ? Feeder terminal blocks and compact buses ? Normally open and normally closed front and side mounted auxiliary contacts ? Shunt trip and undervoltage trip auxiliary contacts ? Door coupling handle ? IP65 enclosure (UL/CSA type 12) For more details on accessories and specifications, see ab The horsepower/kW rating shown in the technical data * on. com is for reference only. The final selection of MPCB/MPSD depends on the actual motor full load current. Installation Instructions Original Instructions VersaView 6300 DC Connector Assembly and Replacement Mounting Clip Catalog Numbers 6300V-DCCONN, 6300V-DCCONN2, 6300V-DCCON3, 6300V-MTGCLIP16 The instructions in this publication apply to the following items: ? DC Power VersaView ? Connector assemblies for 6300 PC and VersaView 6300 monitors ? Replacement mounting clips for VersaView 630P panel PC and Versa View 6300M monitors Required tools for installation The following tools are used to install 6300V-DCCONN, 6300V-DCCONN2, or 6300V-DCCONN3 DC connector assemblies: ? Adjustable torque screwdriver with metric flat blade screwdriver head ? Wire stripper, cutter, And crimping tools ? Shear pliers ? Safety glasses The following tools are used to install the replacement 6300V-MTGCLIP16 mounting clip: ? 1.5 mm hex wrench (two are supplied with the mounting clip) ? Adjustable torque driver with 1.5 mm hex wrench head ? Safety glasses installation DC connector assembly Connector assembly To assemble and connect the connector assembly by reducing DC power cord movement, please perform the following steps.
1. Disconnect the power of the computer. 2. Remove the DC patch panel from the computer chassis. 3. Open the power connector assembly kit (A in Figure 2 on page 3) that came with your PC. 4. Thread the cable tie through the slot in the corresponding connector half (B in Figure 2 on page 3). 5. Strip the end of each DC power cord to the length shown in Figure 1 on page 2. 6. Insert each stripped end into the DC terminal block as shown in Figure 1. Tools required for installation on the topic page 1. Installation of DC connector assembly 1. Installation and replacement of mounting clip 3. Important DC power cables must be stranded copper, and the size should conform to Figure 1 on page 2. 2 Rockwell Automation Publication 6300V-IN003A-EN-P-2021 January VersaView 6300 DC Connector Assembly and Replacement Mounting Clip Installation Instructions 7. Tighten the screws on the top of the terminal block to secure the DC power cord to the torque value in Figure 1.8. Slide the connector half together with the attached tie wrap onto the end of the DC terminal block (C in Figure 2 on page 3). 9. Tighten the cable tie to make it close to the terminal wire. 10. Use cutting pliers to cut the excess part of the cable tie (D in Figure 2 on page 3). 11. Install the white label supplied with the kit (E in Figure 2 on page 3). 12. Align and install the other half of the connector clamp to complete the assembly (F in Figure 2 on page 3). 13. Reconnect the DC patch panel and connector assembly to the computer chassis. Tighten the DC terminal block flange screws to the values in Figure 1.14. Turn on the main power switch or circuit breaker. Figure 1 - DC terminal block connection specifications White labels can be used for identification or other information. When properly installed, the two tabs of the half clamp will lock in place. Item Description Attribute 6300V-DCCONN 6200V-DCCONN2 6300V-DCCONN3 1 DC+(24V DC nominal) Recommended power cord size 1.5 mm2 (16 AWG) 2.5 mm2 (14 AWG) 4 mm2 (12 AWG) 2 DC - (0V DC)