婷婷成人丁香五月综合激情,成人精品一区二区三区在线观看,东京热TOKYO综合久久精品,成人A级视频在线观看

您的瀏覽器版本過(guò)低,為保證更佳的瀏覽體驗,請點(diǎn)擊更新高版本瀏覽器

以后再說(shuō)X

歡迎訪(fǎng)問(wèn)瑞昌明盛自動(dòng)化設備有限公司網(wǎng)站!

圖片名

全國訂購熱線(xiàn):
+86 15270269218E-mail:xiamen2018@foxmail.com

ABB >>

A-B>>

GE>>

BENTLY>>

MVME236-3模塊卡件

MVME236-3模塊卡件

MVME236-3模塊卡件持證設計專(zhuān)業(yè)人員應根據ACI 437R、ACI 562、ACI 369R和其他適用的ACI文件對現有結構進(jìn)行徹底的現場(chǎng)調查?,F場(chǎng)調查應至少確定以下內容:a)結構構件的現有尺寸b)裂縫和剝落的位置、尺寸和原因c)現有鋼筋的數量和位置d)鋼筋的腐蝕位置和程度e)存在活性腐蝕f)混凝土的就地抗壓強度g)混凝土的堅固性,應根據ASTM C1583/C1583M進(jìn)行拉脫附著(zhù)力試驗,...

  • 功能特性
  • 參數規格
  • 視頻
  • 應用案例
  • 下載

MVME236-3模塊卡件

    MVME236-3模塊卡件

    持證設計專(zhuān)業(yè)人員應根據ACI 437R、ACI 562、ACI 369R和其他適用的ACI文件對現有結構進(jìn)行徹底的現場(chǎng)調查?,F場(chǎng)調查應至少確定以下內容:a)結構構件的現有尺寸b)裂縫和剝落的位置、尺寸和原因c)現有鋼筋的數量和位置d)鋼筋的腐蝕位置和程度e)存在活性腐蝕f)混凝土的就地抗壓強度g)混凝土的堅固性,應根據ASTM C1583/C1583M進(jìn)行拉脫附著(zhù)力試驗,以確定FRP系統可能安裝在混凝土上的表面上混凝土的抗拉強度。應根據ACI 562要求使用芯材確定混凝土的現場(chǎng)抗壓強度?,F有結構的承載能力應基于現場(chǎng)調查、設計計算和圖紙審查中收集的信息,并通過(guò)分析方法確定。如果認為合適,可將負載測試或其他方法納入整體評估過(guò)程。用于提高現有構件強度的FRP系統應根據第9章至第15章進(jìn)行設計,其中包括對荷載限制、合理荷載路徑、溫度和環(huán)境對FRP系統的影響

    荷載考慮以及鋼筋腐蝕對FRP系統完整性的影響的全面討論。1.2.1.1加固極限通常,為了防止FRP系統受損時(shí)構件突然失效,施加加固極限,以限制用FRP系統加固的構件承載能力的增加。其理念是,FRP鋼筋的損失不應導致構件失效。第9章提供了具體指南,包括評估FRP系統損失后構件完整性的荷載組合。1.2.1.2防火和生命安全FRP加固結構應符合適用的建筑和防火規范。根據適用的建筑規范,根據建筑物的分類(lèi),安裝應符合ASTM E84規定的煙霧產(chǎn)生和火焰蔓延等級。涂層(Apicella和Imbrogno 1999)和隔熱系統(Williams等人2006)可用于限制煙霧和火焰蔓延。由于大多數FRP材料在高溫下會(huì )退化,因此假設外部粘結FRP系統的強度在火災中完全喪失,除非能夠證明FRP在火災所需的持續時(shí)間內仍然有效。通過(guò)使用某些樹(shù)脂、涂層、絕緣系統或其他防火方法,可以提高FRP加固混凝土構件的耐火性(Bisby等人,2005b)。

    Certified design professionals shall conduct a thorough site investigation of existing structures in accordance with ACI 437R, ACI 562, ACI 369R and other applicable ACI documents. The site investigation shall at least determine the following contents: a) the existing size of structural members b) the location, size and cause of cracks and spalling c) the number and location of existing reinforcement d) the location and extent of corrosion of reinforcement e) the presence of active corrosion f) the in-situ compressive strength of concrete g) the soundness of concrete, and the pull off adhesion test shall be conducted according to ASTM C1583/C1583M, To determine the tensile strength of the concrete on the surface on which the FRP system may be installed. The field compressive strength of concrete shall be determined using cores in accordance with ACI 562. The bearing capacity of the existing structure shall be based on the information collected in the field investigation, design calculation and drawing review, and shall be determined by analysis method. If deemed appropriate, load testing or other methods may be incorporated into the overall evaluation process. FRP systems used to improve the strength of existing members shall be designed in accordance with Chapters 9 to 15, including the effects on the FRP system of load limits, reasonable load paths, temperature and environment

    A comprehensive discussion of load considerations and the effect of rebar corrosion on the integrity of FRP systems. 1.2.1.1 Reinforcement limit Generally, in order to prevent the member from suddenly failing when the FRP system is damaged, the reinforcement limit is imposed to limit the increase in the bearing capacity of the member strengthened with the FRP system. The idea is that the loss of FRP reinforcement should not lead to failure of the member. Chapter 9 provides specific guidance, including load combinations to assess the integrity of members after loss of the FRP system. 1.2.1.2 Fire and life safety FRP reinforced structures shall comply with applicable building and fire codes. The installation shall comply with the smoke generation and flame spread rating specified in ASTM E84 according to the applicable building code and the classification of the building. Coatings (Apicella and Imbrogno 1999) and thermal insulation systems (Williams et al. 2006) can be used to limit smoke and flame propagation. Since most FRP materials will deteriorate at high temperatures, it is assumed that the strength of the externally bonded FRP system will be completely lost in a fire unless it can be demonstrated that the FRP remains effective for the required duration of the fire. The fire resistance of FRP reinforced concrete members can be improved by using certain resins, coatings, insulation systems, or other fire protection methods (Bisby et al., 2005b).

    fa405aeea632aa6912154382925a28b_副本.jpg

    ABB PM864AK01.jpg

    12.jpg

    微信圖片_20211117105502.png



    品牌:  Motorola 

    型號:MVME236-3 

    產(chǎn)地:美國

    質(zhì)保:365天

    成色:全新/二手

    發(fā)貨方式:快遞發(fā)貨


圖片名 客服

在線(xiàn)客服 客服一號