MVME197LE-128處理器模塊
注:-在存在異常高水平EMI的情況下,可能需要采取特殊措施,例如靠近焊接或感應加熱設備或靠近無(wú)線(xiàn)電發(fā)射器/收發(fā)器。導電橡膠非導電橡膠軟電線(xiàn)芯軟銅線(xiàn)芯將信號發(fā)送給評估人員90°45°45°“接觸”區域5 22常規檢查和測試記錄(見(jiàn)第6.2.2節和6.2.3節)日期檢查意見(jiàn)3.0安全系統的安裝僅使用440F-A0020氰基丙烯酸酯。氰基丙烯酸酯粘合劑確保持久密封和高防護等級達到IP65。3.1安裝“C”軌道“C”軌電纜連接器,將蓋子封閉到控制單元或下一個(gè)帶電阻器的型材連接器21 6 6.2.4維修在Safedge系統或機器控制系統上工作之前,隔離機器和Safedge系統的電源。遵守電氣安全預防措施。用戶(hù)維修僅限于更換新的Safedge系統部件。如果出現任何問(wèn)題,應將裝置退還給供應商。應使用熱縮對接接頭對連接線(xiàn)進(jìn)行任何維修。更換任何零件后,必須對更換的零件進(jìn)行6.2.2和6.2.3所示的檢查和測試,并特別注意。篡改零部件將使保修失效。如果DIN導軌(440F-C251D)控制單元上的質(zhì)量密封損壞,則保修無(wú)效警告維護或維修操作后,必須正確重新安裝所有緊固件、電纜保護裝置等。
未能做到這一點(diǎn)或使用未經(jīng)批準的部件可能會(huì )導致Safedge系統無(wú)法達到其規定的性能。3.1.1安裝“C”型導軌3.2安全型材的組裝和安裝3.2.1將安全型材切割成一定長(cháng)度。無(wú)滑行室的型材應使用橡膠剪進(jìn)行切割。帶有滑行室的型材應使用細齒鋸切割。安裝時(shí)鉆孔(未提供緊固件)20 6.2.1型材清潔型材應保持無(wú)沉積物,如切屑和其他材料,以防止損壞或死區。允許使用溫水和溫和的清潔劑清潔表面區域。不要使用溶劑。6.2.2日常維護檢查和測試-(建議每周或維修后)停止機器,清潔型材并干燥。檢查型材表面是否損壞。任何刺穿型材的損壞都可能讓材料或液體進(jìn)入。必須立即處理。檢查所有端蓋、拐角和接頭是否牢固且無(wú)損壞。必須立即更換損壞的零件。測試配置文件操作??赡苄枰獌蓚€(gè)人,一人按下配置文件,一人觀(guān)察控制單元的操作。在使用手動(dòng)復位模式的系統上,必須連續按下復位按鈕。檢查配置文件未按下時(shí)RUN“綠色”LED是否亮起,STOP“紅色”LED是否點(diǎn)亮。啟動(dòng)機器,按下配置文件并檢查機器是否立即停止。如果這些檢查發(fā)現任何問(wèn)題,在糾正之前,不要使用機器。將所有檢查和測試記錄在書(shū)面日志中。6.2.3徹底檢查和測試-(每年兩次或維修后)由電氣和機械工程方面的合格人員進(jìn)行。a) 執行6.2.2 b)中的測試,隔離機器和Safedge系統的電源。
Note: - In the case of abnormally high levels of EMI, special measures may be required, such as proximity to welding or induction heating equipment or proximity to radio transmitters/transceivers. Conductive rubber non-conductive rubber flexible wire core Soft copper wire core sends signals to the evaluator 90 ° 45 ° 45 ° "contact" area 5 22 Routine inspection and test records (see sections 6.2.2 and 6.2.3) Date inspection comments 3.0 Only 440F-A0020 cyanoacrylate is used for the installation of the safety system. The cyanoacrylate adhesive ensures a durable seal and a high degree of protection up to IP65. 3.1 Install the cable connector of "C" rail and "C" rail, and close the cover to the control unit or the next profile connector with resistor 21 6 6.2.4 Isolate the power supply of the machine and the Safedge system before maintenance work on the Safedge system or machine control system. Observe electrical safety precautions. User maintenance is limited to replacing new Safedge system components. In case of any problems, the unit shall be returned to the supplier. Any repairs to the connecting wires shall be made using heat shrinkable butt joints. After any parts are replaced, the replaced parts must be inspected and tested as shown in 6.2.2 and 6.2.3, with special attention. Tampering parts will void the warranty. If the quality seal on the DIN rail (440F-C251D) control unit is damaged, the warranty is invalid Warning After maintenance or repair operations, all fasteners, cable protectors, etc. must be reinstalled correctly.
Failure to do so or the use of unapproved components may cause the Safedge system to fail to achieve its specified performance. 3.1.1 Installation of "C" type guide rail 3.2 Assembly and installation of safety profile 3.2.1 Cut the safety profile into a certain length. The profile without sliding chamber shall be cut with rubber shear. Sections with sliding chambers shall be cut with a fine tooth saw. Drilling during installation (fasteners are not provided) 20 6.2.1 Cleaning of profiles Profiles should be kept free of deposits, such as chips and other materials, to prevent damage or dead zones. It is allowed to use warm water and mild detergent to clean the surface area. Do not use solvents. 6.2.2 Daily maintenance inspection and test - (recommended weekly or after maintenance) stop the machine, clean the profile and dry it. Check whether the profile surface is damaged. Any damage that pierces the profile may allow material or liquid to enter. It must be handled immediately. Check that all end caps, corners, and connectors are secure and free from damage. Damaged parts must be replaced immediately. Test configuration file operation. Two people may be required, one to press the configuration file and the other to observe the operation of the control unit. On systems using manual reset mode, the reset button must be pressed continuously. Check whether RUN "green" LED lights up and STOP "red" LED lights up when the configuration file is not pressed. Start the machine, press the configuration file and check if the machine stops immediately. If these checks reveal any problems, do not use the machine until it is corrected. Record all inspections and tests in a written log. 6.2.3 Thorough inspection and testing - (twice a year or after maintenance) by qualified personnel in electrical and mechanical engineering. a) Perform the test in 6.2.2 b) to isolate the power supply of the machine and the Safedge system.