該系統只能在給定的規格范圍內使用,并嚴格按照本手冊中提供的信息進(jìn)行安裝。該系統本身不能防止材料、氣體和輻射噴射造成的危險。對于這些應用,可能需要額外的保護措施,如物理防護。該系統不打算用作外圍防護。該系統不打算用作機器啟動(dòng)或重新啟動(dòng)裝置。機器控制電路的配置必須確保系統輸出觸點(diǎn)的閉合能夠啟動(dòng)機器的啟動(dòng)電路,但不會(huì )直接導致機器啟動(dòng)。機器的啟動(dòng)或重新啟動(dòng)只能通過(guò)在指定的機器控制裝置上進(jìn)行單獨的故意操作來(lái)實(shí)現。該系統不適用于爆炸性環(huán)境。如果需要有關(guān)系統適用于特定應用的進(jìn)一步指導,請聯(lián)系供應商。用作組合跳閘和存在傳感系統圖5用作組合跳閘與存在傳感系統。該系統允許操作員和某些類(lèi)型的車(chē)輛清晰地查看過(guò)程,不受阻礙地進(jìn)入。必須有足夠的空間,以確保從危險區到可接近的墊子周邊的最小距離符合第5節中給出的安全距離計算。所定義的周邊和危險區之間的整個(gè)地面區域必須由墊子傳感器覆蓋,以便在不啟動(dòng)墊子系統的情況下無(wú)法接近或接近危險區。危險墊8用作防護周界內的存在感測系統圖6用作防護周界中的存在感系統。該系統提供存在感測,以防止人員在封閉區域內時(shí)機器啟動(dòng)的任何可能性。當系統以這種方式用作二級保護系統時(shí),第5.4.1節中給出的安全距離計算不適用。周界防護方法應符合所有相關(guān)要求。封閉周界和危險區域之間的整個(gè)地面區域必須由墊子傳感器覆蓋,以便人員在不啟動(dòng)墊子系統的情況下無(wú)法進(jìn)入封閉區域。
危險壓力敏感墊固定防護聯(lián)鎖門(mén)(帶鎖)9第4節-規范控制單元440F-C4000P 440F-C400S 440F-C4000 D符合EN 1760-1、EN 60204-1、EN 954-1:3類(lèi),UL 508響應時(shí)間(墊子按壓-35mS安全觸點(diǎn)打開(kāi))環(huán)境保護IP65 NEMA12外殼-IP40 DIN0470端子-IP20 DIN0470脈沖耐受電壓2500V污染等級III最小開(kāi)關(guān)電流/電壓10mA/10V電源-用戶(hù)選擇110/230V AC(50-60Hz)和24V AC/DC+10%-15%(110V設置也允許在100v±10%下使用)功耗<9 VA 6W繼電器輸出2個(gè)獨立的無(wú)電壓N/O安全觸點(diǎn)1個(gè)無(wú)電壓N/C輔助觸點(diǎn)NB-Aux不得用于外部安全電路保險絲,AC最大5A(快速作用),AC最大2.5A(快速作用的),DC使用類(lèi)別AC-15;4A/250V交流-直流-13;2A/30V DC輸出:遠程復位/指示燈24V DC/0.24W輸入遠程復位開(kāi)關(guān)(2 x N/O)安全輸入4線(xiàn)墊指示燈LED 1電源綠色LED 2自動(dòng)復位模式綠色LED 3手動(dòng)復位模式綠色LED4機器啟用綠色內部控制交流電壓選擇器,自動(dòng)/手動(dòng)復位選擇器內部電源保險絲500mA可更換500mA可替換500mA可換(2個(gè))(2個(gè)關(guān)閉)(1個(gè)關(guān)閉)500mA可重置(1個(gè))工作溫度范圍-10°C至+45°C濕度在+50°C時(shí)敢達90%RH根據IEC 68-2-6進(jìn)行振動(dòng)測試,頻率范圍10-55Hz,每軸位移0.15mm 10個(gè)周期,掃描速率,每分鐘1倍頻程MC-MC接觸器監控回路常閉接觸器回路最大導線(xiàn)尺寸為1 x 1.5mm2絞合1 x 1.5mmm2絞合2 x 1.5mm2,套管剝離,套管剝離5mm,1 x 2.5mm2 5mm,1×2.5mm2 8mm,2 x 2.5mm2實(shí)心導體實(shí)心導體實(shí)心導線(xiàn)端子負端子負端子正/負外加螺釘M2.5螺釘M2.5端子螺釘M3.5安裝在45°處,安裝在45度處,可自行提升至PCB至PCB連接,根據VDE 0110材料,可單獨拆卸的墊圈端子板安裝組C,聚碳酸酯鋼,帶聚碳酸酯聚碳酸酯屏幕固定細節4 x M4孔4 x M6孔35mm,導軌其他。
The system can only be used within the given specification range, and shall be installed in strict accordance with the information provided in this manual. The system itself does not protect against the hazards caused by material, gas and radioactive jets. For these applications, additional protective measures, such as physical protection, may be required. The system is not intended for perimeter protection. The system is not intended to be used as a machine starting or restarting device. The configuration of the machine control circuit must ensure that the closing of the system output contacts can start the starting circuit of the machine, but will not directly cause the machine to start. The starting or restarting of the machine can only be achieved through separate intentional operation on the designated machine control device. The system is not suitable for explosive environments. If you need further guidance on the suitability of the system for a particular application, please contact the supplier. Used as a combined trip and presence sensing system Figure 5 is used as a combined trip and presence sensing system. The system allows the operator and certain types of vehicles to see the process clearly and enter unhindered. There must be sufficient space to ensure that the minimum distance from the danger zone to the perimeter of the accessible mat complies with the safety distance calculation given in Section 5. The entire ground area between the defined perimeter and the hazard area must be covered by a mat sensor so that the hazard area cannot be approached or approached without activating the mat system. The hazard pad 8 is used as a presence sensing system within the protective perimeter Figure 6 is used as a presence sensing system within the protective perimeter. The system provides presence sensing to prevent any possibility of the machine starting when a person is in an enclosed area. When the system is used as a secondary protection system in this way, the safety distance calculation given in Section 5.4.1 is not applicable. The method of perimeter protection shall comply with all relevant requirements. The entire ground area between the enclosed perimeter and the hazardous area must be covered by mat sensors so that personnel cannot enter the enclosed area without activating the mat system.
Dangerous pressure sensitive pad fixed protective interlocking door (with lock) 9 Section 4 - Specification Control unit 440F-C4000P 440F-C400S 440F-C4000 D according to EN 1760-1, EN 60204-1, EN 954-1:3, UL 508 response time (cushion pressing - 35mS safety contact opens) Environmental protection IP65 NEMA 12 housing - IP40 DIN0470 terminal - IP20 DIN0470 pulse withstand voltage 2500V Pollution level III Minimum switching current/voltage 10mA/10V power supply - user selects 110/230V AC (50-60Hz) and 24V AC/DC+10% - 15% (110V setting is also allowed to be used under 100v ± 10%) Power consumption<9 VA 6W relay outputs 2 independent voltage free N/O safety contacts 1 voltage free N/C auxiliary contact NB Aux shall not be used for external safety circuit fuses, AC maximum 5A (fast acting), AC maximum 2.5A (fast acting), DC use category AC-15; 4A/250V AC-DC-13; 2A/30V DC output: remote reset/indicator light 24V DC/0.24W input remote reset switch (2 x N/O) safety input 4 wire pad indicator light LED 1 power supply green LED 2 automatic reset mode green LED 3 manual reset mode green LED 4 machine enable green internal control AC voltage selector, Automatic/manual reset selector internal power fuse 500mA replaceable 500mA replaceable 500mA replaceable (2) (2 off) (1 off) 500mA resettable (1 off) Operating temperature range - 10 ° C to+45 ° C Humidity at+50 ° C dare to reach 90% RH Vibration test according to IEC 68-2-6, frequency range 10-55Hz, displacement of each shaft 0.15 mm 10 cycles, scanning rate, One octave per minute MC-MC contactor monitoring circuit Normally closed contactor circuit Maximum conductor size is 1 x 1.5mm2 stranded 1 x 1.5mm2 stranded 2 x 1.5mm2, casing stripping, casing stripping 5mm, 1 x 2.5mm2 5mm, 1 × 2.5mm2 8mm, 2 x 2.5mm2 solid conductor solid conductor solid conductor terminal negative terminal negative terminal plus/minus external screw M2.5 screw M2.5 terminal screw M3.5 is installed at 45 °, installed at 45 °, and can be lifted to PCB to PCB connection by itself. According to VDE 0110 material, separately removable gasket terminal board installation group C, polycarbonate steel, with polycarbonate polycarbonate screen fixing details 4 x M4 holes 4 x M6 holes 35mm, other guide rails.