MVME162PA-242SE機械設備卡件
交流脈沖數字輸出 功率計 交流電脈沖數字輸出輸出功率監視器串行功率表 交流脈沖 功率計 模擬輸出 串行功率計 交流模擬輸出 功率計指示燈 和 電量計 脈沖數字輸出 功率計 和 模擬輸出 功率計交流和 串行功率計交流電和 交流電當? 如果存在電阻即正常運行條件,則向機器控制電路產(chǎn)生信號。如上圖所示,當型材從任何方向按時(shí),頂部導電橡膠條壓縮并接觸中間導電橡膠,從而產(chǎn)生“短路”,整體電阻下降。這由啟動(dòng)機器停機的控制單元監控。將檢測配置文件中的任何單個(gè)故障或配置文件的接線(xiàn)連接,控制單元輸出將進(jìn)入安全狀態(tài)。單個(gè)型材通過(guò)導線(xiàn)軸向連接器或標準連接器相互連接。配置文件通過(guò)兩根導線(xiàn)連接到控制單元??刂茊卧哂型耆徊姹O控的安全繼電器,可以配置該單元,以便檢測到外部接觸器故障??刂茊卧姎夤收戏?第類(lèi)和 的要求,機器控制系統的相關(guān)部分也能滿(mǎn)足這些要求。型材符合 第類(lèi)的要求。系統符合歐洲指令的要求。在工業(yè)環(huán)境中可能出現的干擾條件下,由于其已經(jīng)過(guò)測試和認證,因此可以確保正常運行。注:在存在異常高水平的情況下,可能需要采取特殊措施,例如靠近焊接或感應加熱設備或靠近無(wú)線(xiàn)電發(fā)射機收發(fā)器。導電橡膠非導電橡膠軟電線(xiàn)芯軟銅線(xiàn)芯將信號發(fā)送給評估人員“接觸”區域 常規檢查和測試記錄見(jiàn)第節和節日期檢查意見(jiàn).安全系統的安裝僅使用氰基丙烯酸酯。
AC pulse digital output power meter AC pulse digital output power monitor Serial power meter AC pulse power meter Analog output serial power meter AC analog output power meter Indicator light and coulometer Pulse digital output power meter and analog output power meter AC and serial power meter AC and AC current and AC current If there is resistance that is normal operating conditions, it will generate signals to the machine control circuit. As shown in the above figure, when the profile is in any direction, the top conductive rubber strip compresses and contacts the middle conductive rubber, resulting in a "short circuit" and the overall resistance decreases. This is monitored by the control unit that initiates the machine shutdown. Any single fault in the configuration file or the wiring connection of the configuration file will be detected, and the control unit output will enter the safe state. Individual profiles are connected to each other by wire axial connectors or standard connectors. The configuration file is connected to the control unit by two wires. The control unit has a fully cross monitored safety relay, which can be configured to detect external contactor faults. The electrical faults of the control unit meet the requirements of and, and the relevant parts of the machine control system can also meet these requirements. The profiles meet the requirements of category. The system complies with the requirements of European directives. Under the interference conditions that may occur in the industrial environment, normal operation can be ensured because it has been tested and certified. Note: In the case of abnormally high levels, special measures may be required, such as proximity to welding or induction heating equipment or proximity to radio transmitter transceivers. Conductive rubber non-conductive rubber flexible wire core flexible copper wire core sends signals to the evaluator. See section and section date inspection comments for routine inspection and test records of the "contact" area. Only cyanoacrylate is used for the installation of the safety system.