MVME162-522A庫存備件
從電機安裝面施加杠桿以移除安裝在電機軸上的設備可能會(huì )損壞反饋裝置。在安裝或拆卸過(guò)程中,不要用工具敲擊聯(lián)軸器或皮帶輪。使用車(chē)輪拉拔器從軸的用戶(hù)端施加壓力,以從電機軸上移除任何摩擦配合或卡住的裝置。系列或更小框架尺寸的低慣量無(wú)刷伺服電機年月通過(guò)使用接地母線(xiàn)或大母線(xiàn)的單點(diǎn)并聯(lián)接地系統對所有設備進(jìn)行接地。如有必要,使用額外的電氣降噪技術(shù)來(lái)減少噪聲環(huán)境中的。有關(guān)通過(guò)提高系統級電磁兼容性來(lái)減少影響的更多信息,請參閱《電氣噪聲控制系統設計參考手冊》。構建和安裝電纜正確的電纜布線(xiàn)和小心的電纜結構可提高系統電磁兼容性。按照以下指南制作和安裝電纜盡量縮短電線(xiàn)長(cháng)度。將噪聲敏感接線(xiàn)編碼器和遠離輸入電源和電機電源接線(xiàn)。對于每米英尺的平行敷設,將電纜至少分開(kāi)米英尺。將編碼器電纜屏蔽的兩端接地,并扭轉信號線(xiàn)對,以防止來(lái)自其他設備的。屏蔽電源線(xiàn)按照以下步驟屏蔽電源線(xiàn)。如圖所示,通過(guò)回圈每個(gè)信號線(xiàn)對,驗證單獨的信號線(xiàn)屏蔽是否連接到整個(gè)機箱接地。將驅動(dòng)器上的電源線(xiàn)機箱接地連接處的所有三個(gè)屏蔽夾在一起。注意如果屏蔽未接地,電源電纜的屏蔽上可能存在高壓。確認所有電源電纜屏蔽都接地。注意系列電機在保護接地導體中產(chǎn)生的泄漏電流超過(guò)和或。確保按照驅動(dòng)器安裝說(shuō)明正確接地電機電纜。注意如果屏蔽未接地,電源電纜的屏蔽上可能存在高壓。確認電源電纜中所有屏蔽都接地。系列或更小框架尺寸的低慣量無(wú)刷伺服電機年月電力電纜屏蔽制動(dòng)控制和功率調節永磁制動(dòng)器的直流電源,例如或更小框架的系列伺服電機,需要低紋波電壓的直流電源。電機制動(dòng)器需要繼電器觸點(diǎn)來(lái)打開(kāi)和斷開(kāi)制動(dòng)器線(xiàn)圈的電源。斷電會(huì )導致制動(dòng)器機械接合,但也會(huì )導致觸點(diǎn)處產(chǎn)生電弧,直到剩余制動(dòng)功率充分消散。建議使用客戶(hù)提供的二極管,以防止制動(dòng)器繼電器觸點(diǎn)處產(chǎn)生電弧。用金屬氧化物變阻器代替二極管可以減少機械接合制動(dòng)器的時(shí)間。下圖顯示了客戶(hù)提供的典型制動(dòng)控制部件,包括消弧二極管或。
Applying a lever from the motor mounting surface to remove equipment mounted on the motor shaft may damage the feedback device. Do not knock the coupling or pulley with tools during installation or removal. Use the wheel puller to apply pressure from the user end of the shaft to remove any friction fit or stuck devices from the motor shaft. The low inertia brushless servo motor of series or smaller frame size is used to ground all equipment through a single point parallel grounding system using a grounding bus or a large bus. If necessary, use additional electrical noise reduction technology to reduce noise in the environment. Refer to the Electrical Noise Control System Design Reference Manual for more information on reducing impacts by improving system level EMC. The construction and installation of cables Correct cable routing and careful cable construction can improve the electromagnetic compatibility of the system. Follow the guidelines below to make and install cables to minimize wire length. Connect the noise sensitive wire to the encoder and the wire away from the input power supply and motor power supply. For parallel runs per meter foot, separate the cables at least meters feet apart. Ground both ends of the encoder cable shield and twist the signal wire pair to prevent from coming from other equipment. Shield the power cord Follow the steps below to shield the power cord. As shown in the figure, verify whether the separate signal wire shield is connected to the whole chassis ground by looping back each signal wire pair. Clamp all three shields together at the power cord chassis ground connection on the drive. Note that if the shield is not grounded, there may be high voltage on the shield of the power cable. Verify that all power cable shields are grounded. Note that the leakage current generated by the series motor in the protective grounding conductor exceeds and or. Make sure that the motor cable is properly grounded according to the driver installation instructions. Note that if the shield is not grounded, there may be high voltage on the shield of the power cable. Verify that all shields in the power cable are grounded. Low inertia brushless servo motor of series or smaller frame size DC power supply for shielding brake control and power regulation permanent magnet brake of power cable, such as series servo motor of smaller frame, requires low ripple voltage DC power supply. The motor brake requires relay contacts to open and disconnect power to the brake coil. De energizing causes the brakes to engage mechanically, but also causes arcing at the contacts until the residual braking power is sufficiently dissipated. Customer supplied diodes are recommended to prevent arcing at the brake relay contacts. Replacing diodes with metal oxide varistors can reduce the time for mechanical brake engagement. The following figure shows typical brake control components provided by the customer, including arc suppression diodes or.