Unless the neutral side of the reference power supply is used, it must be fused according to the same specification. Figure and correct installation according to the steps. See the following page. No indicator light. Secondary fuse. Main fuse. Remote reset terminal. Remote reset. Indicator terminal. Contactor. Monitoring terminal. Auxiliary terminal. Safety output terminal. Connection terminal. White. White. Black. Machine. Enable. Green. Automatic reset mode. Green. Manual reset mode. Green. Power. Green. Mode. Set. Manual. Automatic voltage. Set. Date. Check the block diagram. Follow the steps. Correct installation. See the following page. Automatic reset Set the manual reset auxiliary terminal auxiliary terminal safety output terminal monitoring output terminal contactor monitoring terminal remote reset terminal remote reset indication terminal mode setting manual automatic voltage setting date check block diagram to be correctly installed according to the steps. When using or power, switch the voltage selector to or as appropriate. Note When the system is shipped from the factory, the selector is set to. If a or power supply is used, it shall be a wire, including protective lugs connected to the terminals shown. Check the setting of the voltage selector switch, see Step. Do not make any connections to the terminals shown in step. The size of the protective earth wire shall be at least equal to the size of the power line. If a power supply is used, it should be connected to the terminal to ensure correct polarity. Do not make any connections to the terminals shown in step. For, the grounding electrode of the power supply shall be connected to the terminal. The mat connection connects the leads of the mat to the terminals shown. White, white, black and black. Eight quick connect adapters marked to are located on the unit base and provide connections to the pads. Reset Power Reset Optional Power Contactor Control Power Auxiliary Optional Remote Indicator Power Green Automatic Reset Mode Green Manual Reset Mode Green Machine Enable Green White Black White Fuse Replace Up Power Down Power Automatic Manual Mode Set Voltage Set Manual Automatic Date Check Box Connect Mats to Control Unit Diagram Terminate Unused Mat Connections and Connection Mats If there are fewer than pads to connect to the control unit, The other connections must be terminated using the short-circuit plug provided. The required pads shall be sequentially connected to quick connect adapters connected to the outside of the unit. As shown in the figure, terminate the unused connector by disconnecting the installed connector and replacing the short circuit plug. Auxiliary OutputThis terminal provides an auxiliary contact for an indication or alarm device, that is, it closes when the machine enable lamp goes off. They cannot be connected to safety circuits. Note and provide and contact. Safety Outputs These are voltage free terminals used to connect to the machine safety circuit, i.e. they are connected in series with the maximum rating of the machine contactor control circuit.
除非參考電源的中性側,否則必須按照相同的規格進(jìn)行熔斷。圖和按照步驟正確安裝見(jiàn)以下頁(yè)面無(wú)指示燈次級保險絲主保險絲遠程復位端子遠程復位指示端子接觸器監控端子輔助端子安全輸出端子連接端子白色白色黑色黑色機器啟用綠色自動(dòng)重置模式綠色手動(dòng)重置模式綠色電源綠色模式設置手動(dòng)自動(dòng)電壓設置日期勾選框圖按照步驟正確安裝請參閱以下頁(yè)面自動(dòng)重置手動(dòng)重置輔助端子輔助端子安全輸出端子監控輸出端子接觸器監控端子遠程復位端子遠程復位指示端子模式設置手動(dòng)自動(dòng)電壓設置日期復選框圖按照步驟正確安裝。當使用或電源時(shí),將電壓選擇器切換至或視情況而定。注系統從工廠(chǎng)發(fā)貨時(shí),選擇器設置為。如果使用或電源,則應為電線(xiàn),包括連接至所示端子的保護耳。檢查電壓選擇器開(kāi)關(guān)的設置,參見(jiàn)步驟。不要與步驟所示的端子進(jìn)行任何連接。保護接地線(xiàn)的尺寸應至少等于電源線(xiàn)的尺寸。如果使用電源,則應將其連接至端子,以確保極性正確。不要與步驟所示的端子進(jìn)行任何連接。對于,電源的接地極應連接到端子。墊子連接將墊子的引線(xiàn)連接到所示的端子。白色,白色,黑色黑色。八個(gè)標有至的快速連接適配器位于裝置底座上,并提供與墊子的連接。重置電源重置可選電源接觸器控制電源輔助可選遠程指示裝置電源綠色自動(dòng)重置模式綠色手動(dòng)重置模式綠色機器啟用綠色白色黑色白色保險絲更換向上電源向下電源自動(dòng)手動(dòng)模式設置電壓設置手動(dòng)自動(dòng)日期勾選框將墊連接到控制單元圖終止未使用的墊連接和連接墊如果要連接到控制單元的墊少于個(gè),則必須使用提供的短路插頭終止其他連接。所需的墊子應按順序至連接到裝置外部的快速連接適配器。如圖所示,通過(guò)斷開(kāi)安裝的連接器并更換短路插頭來(lái)終止未使用的連接器。輔助輸出該端子提供適用于指示或報警裝置的輔助觸點(diǎn)即,當機器啟用燈熄滅時(shí)閉合。它們不能連接到安全電路。注和提供和觸點(diǎn)。安全輸出這些是用于連接到機器安全電路的無(wú)電壓端子,即,它們與機器接觸器控制電路最大額定值串聯(lián)連接。