應使用額定值適當的保險絲對其進(jìn)行外部保護。對于一個(gè)接觸器,使用連接端子和的端子和。對于具有兩個(gè)獨立控制電路即雙通道系統的兩個(gè)接觸器,使用和連接到一個(gè)接觸器控制電路,使用和連接到另一個(gè)接觸器。參見(jiàn)圖。和,用于與機器控制電路的典型接口示例。注意安全輸出應通過(guò)硬接線(xiàn)直接連接到機器主控制元件接觸器。它們不得通過(guò)任何元件連接,例如普通繼電器等,這些元件未適當指定用于安全相關(guān)功能。接觸器監控控制單元配有這些連接的端子。當鏈路被移除時(shí),它們可以連接到機器接觸器上的正向引導輔助觸點(diǎn),以監控雙通道控制系統中的接觸器。如果一個(gè)接觸器無(wú)法隔離在故障被糾正之前,墊子控制單元的控制線(xiàn)圈斷電時(shí)的功率將不允許另一個(gè)接觸器通電。遠程復位否這些端子用于連接遠程復位按鈕。這必須是一個(gè)無(wú)瞬時(shí)按鈕裝置,其位置可提供檢測區域的全貌。僅限。如果從控制單元上看不到危險區域的全貌,則斷開(kāi)接線(xiàn)盒上控制單元蓋上的復位開(kāi)關(guān)的電線(xiàn),以禁用控制單元的復位功能。遠程復位指示如果與發(fā)光的按鈕遠程復位開(kāi)關(guān)一起使用,將顯示何時(shí)需要復位墊子系統。這些端子用于連接燈泡。短路插頭手動(dòng)復位自動(dòng)復位開(kāi)關(guān)。將開(kāi)關(guān)設置為所需設置。手動(dòng)復位模式自動(dòng)復位模式。根據建立的電壓和模式設置標記并簽署標簽。標記為至的八個(gè)六通接頭。這些接頭是控制單元的墊連接,并連接到單元外部的外部快速連接插頭。重新檢查接線(xiàn)連接,包括機器控制系統接線(xiàn)的連接或修改。更換蓋。將蓋固定在相關(guān)單元上。斷開(kāi)機器原動(dòng)機與最終接觸器的連接,使機器無(wú)法移動(dòng)。
They shall be externally protected by suitably rated fuses. For a contactor, use terminals and that connect terminals and. For two contactors with two independent control circuits, i.e. dual channel system, use and connect to one contactor control circuit and use and connect to the other contactor. See Fig. And for typical interface examples with machine control circuits. Note that the safety output should be hardwired directly to the machine's main control element contactor. They must not be connected by any element, such as a common relay, which is not properly designated for safety related functions. The contactor monitoring control unit is equipped with terminals for these connections. When the links are removed, they can be connected to the positive pilot auxiliary contacts on the machine contactors to monitor the contactors in the dual channel control system. If one contactor cannot be isolated before the fault is corrected, the power when the control coil of the mat control unit is de energized will not allow another contactor to be energized. Remote reset No These terminals are used to connect the remote reset button. This must be a device without instantaneous button, whose position can provide a full view of the detection area. Only. If the full view of the hazardous area cannot be seen from the control unit, disconnect the wire of the reset switch on the control unit cover on the junction box to disable the reset function of the control unit. The remote reset indication, if used in conjunction with the illuminated push button remote reset switch, will show when the mat subsystem needs to be reset. These terminals are used to connect the bulbs. Short circuit plug manual reset automatic reset switch. Set the switch to the desired setting. Manual reset mode Automatic reset mode. Mark and sign the label according to the established voltage and mode. Eight six way connectors marked to. These connectors are pad connections for the control unit and are connected to the external quick connect plug outside the unit. Recheck the wiring connection, including the connection or modification of the machine control system wiring. Replace the cover. Secure the cover on the relevant unit. Disconnect the machine prime mover from the final contactor so that the machine cannot move.