t或通過(guò)通信發(fā)出停止命令,參見(jiàn)第6–6頁(yè)第6.2.4節:功能代碼05:執行操作。n電源系統n[ENTER]了解更多標稱(chēng)系統頻率:60 Hz范圍:50 Hz,60 Hz,可變系統相位順序:ABC范圍:ABC,ACB速度2相位順序:ABC范圍:ABC、ACB僅當啟用雙速電機保護時(shí)才可見(jiàn)n串行通信控制n[ENTEP]了解更多串行通信控制:關(guān)閉范圍:打開(kāi)、關(guān)閉分配啟動(dòng)控制繼電器:輔助2范圍:輔助2、輔助2和輔助3,輔助3 ENTER ESCAPE?信息ESCAPE MESSAGE ESCAPE ENTER ESCAPE?MESSAGE ESCAPE GE Multilin 469電機管理繼電器4-15 4設定值4.3 S2系統設置4 4.3.5降低電壓路徑:設定值×S2系統設置×降低電壓469可以控制降低電壓?jiǎn)?dòng)器從降低到滿(mǎn)電壓的過(guò)渡。該轉換可能基于“僅限電流”、“電流和計時(shí)器”或“電流或計時(shí)器”(以先到者為準)。當469測量到無(wú)電機電流向某個(gè)電機電流值的轉變時(shí),假設會(huì )發(fā)生“啟動(dòng)”(通常電流會(huì )迅速上升到超過(guò)FLA的值,例如3×FLA)。此時(shí),REDUCED VOLTAGE START TIMER(降低電壓?jiǎn)?dòng)定時(shí)器)用編程值(秒)初始化。?如果選擇“僅限電流”,當電機電流低于用戶(hù)編程的轉換水平時(shí),將通過(guò)激活指定的輸出繼電器1秒來(lái)啟動(dòng)轉換。如果計時(shí)器在轉換啟動(dòng)之前到期,則將發(fā)生不完整順序跳閘,激活指定的跳閘繼電器。?如果選擇“電流或定時(shí)器”,當電機電流低于用戶(hù)編程的轉換水平時(shí),將通過(guò)激活指定的輸出繼電器1秒來(lái)啟動(dòng)轉換。如果計時(shí)器在轉換啟動(dòng)之前到期,則無(wú)論如何,轉換都將啟動(dòng)。?如果選擇了“電流和定時(shí)器”,當電機電流低于用戶(hù)編程的轉換水平且定時(shí)器到期時(shí),將通過(guò)激活指定的輸出繼電器1秒來(lái)啟動(dòng)轉換。如果計時(shí)器在電流低于過(guò)渡電平之前到期,則將發(fā)生不完整順序跳閘,激活指定的跳閘繼電器。圖4–1:降壓?jiǎn)?dòng)接觸器控制電路n降壓n[ENTER]更多降壓?jiǎn)?dòng):關(guān)閉范圍:打開(kāi),關(guān)閉分配控制繼電器:輔助3范圍:輔助2、輔助2和輔助3、輔助3轉換開(kāi)啟:僅限電流范圍:電流或定時(shí)器、電流和定時(shí)器分配跳閘繼電器:跳閘范圍:跳閘、跳閘和輔助2、跳閘和Aux2和輔助3,跳閘和輔助3降壓?jiǎn)?dòng)電平:100%FLA范圍:25至300%,步進(jìn)1降壓?jiǎn)?dòng)定時(shí)器:200 s范圍:1至600 s,步進(jìn)為1回車(chē)退出信息退出信息退出消息退出消息退出808724A1.CDR CC1 CC2 469塊跳閘停止啟動(dòng)降壓接觸器全電壓接觸器CC1密封469 R3輔助CC2密封4-16 469電機管理繼電器GE Multiline 4.3 S2系統設置4
t or stop command via communications, see Section 6.2.4: Function Code 05: Execute Operation on page 6–6. n POWER SYSTEM n [ENTER] for more NOMINAL SYSTEM FREQUENCY: 60 Hz Range: 50 Hz, 60 Hz, Variable SYSTEM PHASE SEQUENCE: ABC Range: ABC, ACB SPEED2 PHASE SEQUENCE: ABC Range: ABC, ACB Seen only if 2-Speed Motor Protection is enabled n SERIAL COM. CONTROL n [ENTER] for more SERIAL COMMUNICATION CONTROL: Off Range: On, Off ASSIGN START CONTROL RELAYS: Auxiliary2 Range: Auxiliary2, Aux2 & Aux3, Auxiliary3 ENTER ESCAPE e e MESSAGE ESCAPE MESSAGE ESCAPE ENTER ESCAPE e e MESSAGE ESCAPE GE Multilin 469 Motor Management Relay 4-15 4 SETPOINTS 4.3 S2 SYSTEM SETUP 4 4.3.5 REDUCED VOLTAGE PATH: SETPOINTS ?× S2 SYSTEM SETUP ?× REDUCED VOLTAGE The 469 can control the transition of a reduced voltage starter from reduced to full voltage. That transition may be based on "Current Only", "Current and Timer", or "Current or Timer" (whichever comes first). When the 469 measures the transition of no motor current to some value of motor current, a ’Start’ is assumed to be occurring (typically current will rise quickly to a value in excess of FLA, e.g. 3 × FLA). At this point, the REDUCED VOLTAGE START TIMER is initialized with the programmed value in seconds. ? If "Current Only" is selected, when the motor current falls below the user's programmed Transition Level, transition will be initiated by activating the assigned output relay for 1 second. If the timer expires before that transition is initiated, an Incomplete Sequence Trip will occur activating the assigned trip relay(s). ? If "Current or Timer" is selected, when the motor current falls below the user's programmed Transition Level, transition will be initiated by activating the assigned output relay for 1 second. If the timer expires before that transition is initiated, the transition will be initiated regardless. ? If "Current and Timer" is selected, when the motor current falls below the user's programmed Transition Level and the timer expires, transition will be initiated by activating the assigned output relay for 1 second. If the timer expires before current falls below the Transition Level, an Incomplete Sequence Trip will occur activating the assigned trip relay(s). Figure 4–1: REDUCED VOLTAGE START CONTACTOR CONTROL CIRCUIT n REDUCED VOLTAGE n [ENTER] for more REDUCED VOLTAGE STARTING: Off Range: On, Off ASSIGN CONTROL RELAYS: Auxiliary3 Range: Auxilary2, Aux2 & Aux3, Auxiliary3 TRANSITION ON: Current Only Range: Current Only, Current or Timer, Current and Timer ASSIGN TRIP RELAYS: Trip Range: Trip, Trip & Aux2, Trip & Aux2 & Aux3, Trip & Aux3 REDUCED VOLTAGE START LEVEL: 100% FLA Range: 25 to 300% in steps of 1 REDUCED VOLTAGE START TIMER: 200 s Range: 1 to 600 s in steps of 1 ENTER ESCAPE e e MESSAGE ESCAPE MESSAGE ESCAPE MESSAGE ESCAPE MESSAGE ESCAPE MESSAGE ESCAPE 808724A1.CDR CC1 CC2 469 BLOCK TRIP STOP START REDUCED VOLTAGE CONTACTOR FULL VOLTAGE CONTACTOR CC1 SEAL IN 469 R3 AUX CC2 SEAL IN 4-16 469 Motor Management Relay GE Multilin 4.3 S2 SYSTEM SETUP 4